3 phase rogowski coil ct 1000A/333mv with 2m wire lead

Availability:

Flexible rogowski coil current transformer  sensor with 0.33v-5v output

Rogowski Coil current sensors are designed for fast and easy installation on existing primary conductors/
BUS bars. The split design permits non-contact AC current or current pulse measurement without requiring that
the primary conductor be taken offline and disconnected for the current sensor installation. This method provides
for the safe, easy and portable measurement of current.
A current sensor that is based upon the Rogowski Coil principle offers significant advantages over the standard
magnetic core current transformer products. Specifically, since the sensor does not incorporate a magnetic core,
magnetic core saturation (the point where incremental increases in magnetic flux are not reflected in proportional
increases in secondary signal outputs) is avoided

Flexible rogowski coil current transformer sensor

Features:
· Capable of accommodating a range of primary conductor sizes.
· Characterized by high sensitivity, accuracy, linearity, minimum phase shift.
· Suitable for harsh operating environments (temperature, humidity, EMI).
· Current Range: 10A to 100kA
· Accuracy: < 1%
· Phase Shift: < 1 degrees at 50/60Hz (< 0.5 degrees typical) /li>
· Linearity: ±0.2% from 10% to 100% of rated primary current
· Primary Conductor Position Sensitivity: ± 2% maximum
· Influence of External Field: ± 1.5% maximum
· Coil Working voltage: 1000VRMS or 1000VDC
· Coil Dielectric Surge Withstand: 5kVRMS for 1 minute
· Operating temperature: -20ºC to +60ºC
· Leads: Shielded cable, or as per customer need

Flexible rogowski coil current transformer sensor

Rated current (rms)

10A-100KA

Output

mV (without integrator)

0-0.33v 0-5V  0-10vAC(with integrator)

Power supply

5v 9V 12v 24v

Coil length

20cm-200cm

Tube

UL material

Wire lead

Shielded cable

Isolation voltage

3500V

Operating temperature

-25℃-+70℃

Frequency

1Hz-1MHz

Accuracy

±1%

Flexible rogowski coil current transformer sensor

3 phase rogowski coil ct 1000A/333mv with 2m wire lead

Three phase flexible rogowski coil current transformer sensor

3 phase rogowski coil ct 1000A/333mv with 2m wire lead

Three phase rogowski coils with energy meter

3 phase rogowski coil ct 1000A/333mv with 2m wire lead3 phase rogowski coil ct 1000A/333mv with 2m wire lead3 phase rogowski coil ct 1000A/333mv with 2m wire lead

Three Phase flexible rogowski coil current transformer sensor with meter 0.33v

3 phase rogowski coil ct 1000A/333mv with 2m wire lead3 phase rogowski coil ct 1000A/333mv with 2m wire lead3 phase rogowski coil ct 1000A/333mv with 2m wire lead3 phase rogowski coil ct 1000A/333mv with 2m wire lead3 phase rogowski coil ct 1000A/333mv with 2m wire lead

Company infomation- Flexible rogowski coil current transformer sensor

3 phase rogowski coil ct 1000A/333mv with 2m wire lead 3 phase rogowski coil ct 1000A/333mv with 2m wire lead 3 phase rogowski coil ct 1000A/333mv with 2m wire lead 3 phase rogowski coil ct 1000A/333mv with 2m wire lead 3 phase rogowski coil ct 1000A/333mv with 2m wire lead


Previous: 
Next: 
Since its establishment in 1995, JIANGYIN SPARK ELECTRONIC TECHNOLOGY CO.,LTD has become a manufacturing enterprise integrating R&D and production. At present, it has been awarded as a high-tech enterprise .......
QUICK LINKS
Home
PRODUCT CATEGORY
Flexible Rogowski Coil
CONTACT US
  +86-13806164660
  T+86-18121509957
      F: +86-510-86277533
   kelly@xh-dianzi.com
      Whatsapp:+86-16605105290
   NO.6 Xinyuan Road, JiangYin ,China
Copyright © 2022 JIANGYIN SPARK ELECTRONIC TECHNOLOGY CO.,LTD  Sitemap | Support by Leadong